Specificity and sensitivity of diabetic peripheral neuropathy screened by Michigan neuropathy screening instrument

Zhi-hou Liang,Qiang Guan,Yue Tan,Zhi Nie
DOI: https://doi.org/10.3321/j.issn:1673-8225.2005.39.011
2005-01-01
Abstract:Aim: To discuss the role of Michigan neuropathy screening instrument (MNSI) in evaluating diabetic peripheral neuropathy, and compare with the results of nerve conduction velocity examination. Methods: Eighty d iabetic patients (38 males and 42 females), including 67 type 2 diabetic patients and 13 type 1 diabetic patients, were selected from the outpatients and inpatients in the Second Affiliated Hospital of Kunming Medical College from February 2003 to May 2004. All the 80 patients were evaluated with MNSI at admission: Appearance of feet: 0 for normal appearance, and 1 for abnormal appearance, the latter included deformed, dry skin, callus, infection; Ankle reflexion: foot flexion as negative (0 point), irresponsivity as positive(1 point), between the above two as doubtful (0.5 point); Vibration perception at great toe: 1 for apallesthesia (patient could not feel fork vibration). When the total score was over 2, the result of MNSI was taken as positive. The nerve conduction velocity was examined with 5-passage electromyograph and evoked instrument. Sensibility of MNSI=number of patients with positive MNSI and at least 2 abnormal nerves through performed nerve conduction/number of patients who at least had 2 abnormal nerves through performed nerve conduction ×100%. Specificity of MNSI= number of patients with negative MNSI/number of patients with normal nerve conduction ×100%. Results: All the 80 patients with diab etic peripheral neuropathy were involved in the analysis of results. 1 Among the indices of MNSI, vibration perception at great toe had the highest abnormal rate (55%, 44/ 80); 11% of the patients (9/80) had abnormal appearance of feet and/or ulceration, and they always had abnormal ankle reflexion or abnormal vibration perception at great toe at the same time. 2 Among the nerve conduction velocity examination, sural nerve and peroneal nerve had the highest abnormal rate, which were 59% (41/80) and 38% (30/80). 3 Of the 80 diabetic patients, the MNSI was positive in 41 cases, including 37 patients had diabetic peripheral neuropathy with the score of MNSI > 2, and 9 patients had diabetic peripheral neuropathy with score of MNSI ≤ 2; The MNSI score was negative in 39 cases, including 9 cases had diabetic peripheral neuropathy and 30 cases were normal. The sensitivity of MNSI for diagnosis of diabetic peripheral neuropathy was 80%, and the specificity was 88%. Conclusion: 1 It is suggested that diabetic periph eral neuropathy is more serious when the abnormal appearance of feet and/or ulceration appears. 2 Nerves of lower limbs have the most probability of being damaged in diabetic patients. 3 MNSI has good sensitivity and specificity in the diagnosis of diabetic peripheral neuropathy, which are 80% and 88% respectively.
What problem does this paper attempt to address?