Evaluation of low-limb function after treatment of patellar bone fractures with domestic made poly-DL-Lactic acid absorbable screw: 6-month follow-up

Jun Xiao,Shu-hua Yang,Wei-hua Xu,Zhe-wei Ye,Shu-nan Ye,Yuan-xin Liang
DOI: https://doi.org/10.3321/j.issn:1673-8225.2005.42.043
2005-01-01
Abstract:AIM: To investigate the effect and safety of the treatment of domestic made poly-DL-lactic acid (PDLLA) absorbable screw on patellar bone fractures. METHODS: Between 2002 and 2003, PDLLA was used to treat 28 cases of patellar bone fractures in the Orthopaedic Department of Union Hospital affiliated to Tongji Medical College, Huazhong University of Science & Technology. At 2-3 days after the operation, the operated limb was moved passively and continuously by the CPM (continue passive move) machine. The patient initiatively moved in the on the 5th day after operation. The patient could walk with no bear by a stick and flex or extend to a larger scope a week later. After 6 weeks, the patient could walk without a stick gradually. All cases were followed up at 1, 2, 4, 12 and 24 weeks after operation and observation was done on the healing time of fractures. The functions of the knees were evaluated.RESULTS: All cases were followed up for an average of 11.7 months (6-20 months). ① The long-term functions of the knee evaluation: The results of the evaluation to the functions of the knee: excellent in 17 cases good in 9 cases general in 2 cases bad in 0 cases. The excellent and good rate was 93%. ② The healing time of fracture: All the fractures had united within 3-4 months without abnormalities or delayed heal 6 cases were quadriceps femoris atrophy and 4 cases recovered 4-6 months after operation and the others recovered 12-16 months later no case with screw loosening or displacement. CONCLUSION: The poly-DL-lactic acid (PDLLA) absorbable screws are well biocompatible and effective. It can provide enough strength to the broken ends in the early-stage of the fractured bones. It is effective and reliable to treat all kinds of patellar fractures with safe and stable fixation. As the fracture healed, the strength of the screw decreased gradually and no stress force block created. It helps bone repair to the normal biology structure and function. The strength can maintain effectively 6 months. At last, it was absorbed and discharged out of body. It can used to treat patellar bone fracture effectively and safely and the function of knee is well. It is the ideal fixation to the patellar bone fracture.
What problem does this paper attempt to address?