Numerical analysis of composite slim floor beams in fire

Lu Xue-Tao,Zhang Su-Mei
2005-01-01
Abstract:Slim-floor construction is one of the composite floor constructions. The slim floor beams, which are partly contained within the floor slab, have good performance under fire. This kind of construction has become popular throughout Europe in recent years for its many advantages. In this paper, based on the constitutive relations of steel and concrete under temperature, the mechanical behavior of the composite slim-floor beams in fire is analyzed with the results of the temperature distribution in composite beams according to paper [1]. The procedures for the numerical analysis of the fire resistance of the composite slim-floor beams can be set forth from the comparison between the test results and the computational results. Then the parameters that affect the fire resistance behavior are discussed by the numeric analysis program made by the authors.
What problem does this paper attempt to address?