Comparison of Ti/BDD and Ti/SnO 2 –Sb 2 O 5 electrodes for pollutant oxidation

Xueming Chen,Furong Gao,Guohua Chen
DOI: https://doi.org/10.1007/s10800-004-6068-0
IF: 2.925
2005-01-01
Journal of Applied Electrochemistry
Abstract:Anodic oxidation is a promising process for degrading toxic and biologically refractory organic pollutants present in wastewater treatment. Proper selection of electrodes is the key to reach effective and economic operation. In this study, two types of electrodes, i.e. the recently developed Ti/BDD and Ti/SnO 2 –Sb 2 O 5 , which is generally believed to be superior to the conventional electrodes, were compared under the same conditions. It was found that the Ti/BDD electrode could mineralize both phenol and reactive dyes effectively. But the Ti/SnO 2 –Sb 2 O 5 electrode could only mineralize phenol. When oxidizing more refractory reactive dyes, it demonstrated very poor activity. In addition, the Ti/BDD electrode had a service life of 264 h in an accelerated life test, but the Ti/SnO 2 –Sb 2 O 5 was irreversibly damaged within several seconds. The direct experimental comparison in the present study indicates that the Ti/BDD electrode is much better than the Ti/SnO 2 –Sb 2 O 5 electrode for pollutant oxidation.
What problem does this paper attempt to address?