Seatests of an all-optical fiber-optic hydrophone system

倪明,李秀林,张仁和,胡永明,孟洲,熊水东,刘阳
DOI: https://doi.org/10.3321/j.issn:0371-0025.2004.06.009
2004-01-01
Abstract:Introduced the principle of fiber-optic hydrophone and how it detected of sound pressure. We fabricated some units of fiber-optic hydrophone, whose size was ø22 mm × 100 mm. Test showed its phase sensitivity was -160 dB (ref 1 rad/Hz1/2) and fluctuation was less than 3 dB and minimum measurable sound pressure was 43.5 dB (at 1 kHz), as much as sea-state zero (SSO). The correlation coefficient of signals, which were sampled by a fiber-optic hydrophone and a standard hydrophone, were over 0.94. A 23-element fiber optic hydrophone array was deployed at Bohai via 1 km fiber optic underwater cable on August, 2002. The sound source was air gun. The correlation coefficients of signals sampled by adjacent elements were over 0.98 and the array had a good beam directionality. Progress on fiber-optic hydrophone implied a great future for application.