Prediction of Sodium Boiling Caused by Total Blockage of a Single Subassembly Inlet in the Chinese Experimental Fast Reactor

石晓波,罗锐,王洲,杨献勇,穆瑞云
DOI: https://doi.org/10.3321/j.issn:1000-0054.2004.11.034
2004-01-01
Abstract:The total instantaneous blockage of a single subassembly inlet in the liquid metal cooled fast breeder reactor LMFBR may cause very severe consequences which should be predicted. The SCARABEE BE+1 test until onset of cladding motion was simulated to verify the numerical model. The model was then applied to the Chinese experimental fast reactor CEFR to predict the phenomenon after a blockage. The results show that the outlet flow oscillation and rapid increase of the heat flux through the hexcan-wall in the SCARABEE BE+1 test also occur during boiling in CEFR. In the SCARABEE BE+1 test, sodium reentry delays the onset of dryout until 2.2 s after boiling onset, while boiling lasts only 0.3 s before dryout onset in the CEFR. The difference occurs mainly because the CEFR subassembly is composed of many more fuel pins with much larger power per unit volume.
What problem does this paper attempt to address?