A METHOD OF DYNAMIC SIMULATION FOR TEMPERATURE PROFILE IN A FOUR-CORNER FIRED BOILER BASED ON ON-LINE MONITORING OF AIR AND COAL

周乃君,夏小霞,欧育辉,周正明
DOI: https://doi.org/10.3321/j.issn:0258-8013.2004.10.044
2004-01-01
Abstract:Considering the temperature distribution in tangential fired pulverized coal boiler is difficult to be measured and monitored, two-stage numerical simulation was put forward. First, multi-field coupling simulation for a lot of typical work conditions was carried out off-line with the software CFX-4.3, and then an expression of temperature varying with operating parameter was obtained. According to real-time operating parameters, the temperature in arbitrary point of the furnace can be calculated by using this expression. Thus temperature profile can be shown on-line and monitoring for combusting state in the furnace is realized. The simulating model was checked by the parameters measured in a operating boiler, DG130-9.8/540, and the maximum of relative error is less than 12% (maximum of absolute error is less than 120℃),which show that two-stage simulation method is reliable and able to satisfy the requirement of industrial application. Based on this method, a combustion monitoring system had been developed and applied successfully in the thermal power plant.
What problem does this paper attempt to address?