THE PERFORMANCE OF SOLAR COOLING TUBE WITH NON-TRACKING CONCENTRATOR

徐海峰,刘震炎
DOI: https://doi.org/10.3321/j.issn:0254-0096.2003.06.004
2003-01-01
Abstract:The compound parabolic concentrator (CPC), a kind of non-tracking concentrator, was presented for a developed solar cooling tube whose adsorption/collector uses the evacuated insulation technology and selective coatings. It can enhance to absorb solar radiation for the adsorbent bed of the cooling tube, and increase the cooling capacity and the coefficient of performance (COP) of a single solar cooling tube. The CPC reflector combined with the solar cooling tube was analyzed and designed, and the relations of the parameters of acceptance half-angle, average number of reflection <n>, optical efficiency and concentration ratio were discussed. The results of both theory and experiment showed that the CPC reflector can raise the temperature of adsorbent bed and greatly increase the desorption capacity. The cooling capacity of the single solar cooling tube with CPC reflector increases by 60-67% than the one with flat reflector made of rolled aluminium, and COP increases by 16-21%.
What problem does this paper attempt to address?