Amperometric immunosensor based on mercapto carboxylic acid self-assembled monolayer for phytohormone indoleacetic acid assay

Chunxiang Li,Jin Li,Langtao Xiao,Güoli Shen,Ruqin Yu
DOI: https://doi.org/10.3321/j.issn:0567-7351.2003.05.026
2003-01-01
Acta Chimica Sinica
Abstract:A competitive binding assay used to determine hapten IAA with the aid of HRP-IAA conjugate has been developed. It is based on the ordered, stable mercapto self-assembled monolayer formed on gold surface, which immobilized IgG with covalent bond. The features of the substrate reaction under different conditions were investigated by cyclic voltammetry and the assay conditions were optimized. Under applied potential of -200 mV, the response current is linear with Ig[IAA], over a concentration range of 5.68 × 10-7 - 2.83 × 10-5 mol/L with a correlation coefficient of 0.9915. The sensor was applied for the determination of IAA sample with satisfactory results.
What problem does this paper attempt to address?