Determination and dissolution of propylene glycol mannurate sulfate by HPLC

赵峡,吕志华,徐家敏
DOI: https://doi.org/10.3321/j.issn:1001-2494.2002.07.017
2002-01-01
Abstract:OBJECTIVE: To establish a HPLC method for the determination of propylene glycol mannurate sulfate (PGMS) and its dissolution. METHODS: Aminex HPX-87H column (300 mm × 7.8 mm) was used. 0.005 mol·L-1 H2SO4 was used as the mobile phase at the flow rate of 0.5 mL·min-1. D-glucuronic acid was used as the internal standard. The column temperature was 60°C with the detection wavelength at 210 nm. RESULTS: The calibration curve was linear over the range of 100∼2 000 μg·mL-1, the average recovery was 97.32% with RSD = 2.54% (n = 6) and its detection limit was 4μg·mL-1. CONCLUSION: This method was proved to be simple, rapid, reliable and reproducible.
What problem does this paper attempt to address?