Extracting and Separating Method Type Gas-Liquid Two-Phase Flow Meter by Using Rotational Drum as Distributor

王栋,林益,林宗虎
DOI: https://doi.org/10.3321/j.issn:0253-987X.2002.05.004
2002-01-01
Abstract:A extracting and separating method (ESM) type gas-liquid two-phase flow meter was proposed and tested in an air-water two-phase flow loop. By using a rotational drum distributor, a fraction (about 20%) of the two-phase mixture was proportionally extracted and conducted to a small compact separator which separate the mixture into single phase gas and liquid. Conventional flowmeters were employed to meter the separated gas and liquid respectively. The total flow rates of each phase were then determined according to these metered values and the extraction ratios. After the separated gas and liquid had been metered they were returned to the main stream again. Because only a small portion of the total flow is extracted the separator can be reduced in size greatly compared to the conventional separation method. Experiments confirmed that the extraction ratio is equal to the ratio of extraction channel number to the total flow channel number inside the drum and independent of flow patterns. The average error of flow rates measurement was less than 5%.
What problem does this paper attempt to address?