Second Chinese National Registry of Catheter Ablation of Tachyarrhythmia

Da Yi Hu
DOI: https://doi.org/10.1177/021849230100900212
2001-01-01
Abstract:The Chinese national registry of radiofrequency catheter ablation of tachyarrhythmias included data from 134 hospitals over 3 years from January 1995. Ablation was used in 24,343 patients, with 97% success, 3.1% recurrence, 0.95% complications, and 0.02% mortality overall. Accessory pathway ablation was performed in 15,617 patients (64.2%) with atrioventricular reciprocating tachycardia (97% success, 2.8% recurrence, 1% complications). The 6,746 patients (27.7%) with atrioventricular nodal reentrant tachycardia underwent slow pathway ablation (98% success, 2.7% recurrence, 1% complications). Focal ablation in the right or left ventricle was attempted in 1,025 patients (4.2%) with idiopathic or organic ventricular tachycardia (87% success, 6.8% recurrence, 0.5% complications). The 419 patients with atrial tachycardia underwent atrial focal ablation (84% success, 9.9% recurrence, 0% complications). Focal or linear ablation of the isthmus was conducted in 366 patients with atrial flutter (89% success, 10% recurrence, 1.1% complications). Atrioventricular junction ablation was used for rate control in 170 patients with atrial fibrillation (99% success). Multiple atrial linear ablations for rhythm control were 56% successful. Success rates and incidence of complications depended on the type of tachyarrhythmia, and remained constant over the 3 years. Further improvements in technique are needed to improve success rates and decrease the incidence of complications.