Chemiluminescence Detection from Sonodynamic Action in Vitro and in Vivo

YH He,D Xing,Y Guihong,K Ueda
DOI: https://doi.org/10.1117/12.446658
2001-01-01
Abstract:In this work, chemiluminescence method was engaged for the first time to detect the active oxygen spices during sonocynamic action both in vitro and in vivo. We used CLA derivatives, which can efficiently react with singlet oxygen (O-1(2)) or superoxide anion (O-2(-)) to emit light, and luminol, which can be oxidized by a variety of free radicals to emit photons, to real-timely detect oxygen free radical formation in the sonosensitization of two sonosensitizer ATX-70 and HpD. The results show that O-1(2) is involved in the sonosensitization. The mechanism of sonosensitizing was discussed. In vivo experiments, tumor imaging by sonodynamic chemiluminescence detection methods was established. This method could have potential applications in clinics for early-stage tumor diagnosis.
What problem does this paper attempt to address?