Three-dimensional Photography Method for Phase Distribution Measurements in Bubbly Flows

宋蔷,罗锐,杨献勇,王洲
DOI: https://doi.org/10.3321/j.issn:1000-0054.2001.10.020
2001-01-01
Abstract:Simultaneous measurements of the void fraction and the interfacial area concentration to describe the phase distribution in bubbly flows are of great importance for research on bubbly flows with nonuniform bubble size or significant bubble deformation. A nonintrusive 3D stereophotography method was designed to measure the phase distribution in bubbly flow. In an experimental system to measure bubbly flows in a vertical pipe, a 45° mirror was used to reflect the side view of the flow and a camera was used to simultaneously take the flow images from the side view and front view. Each bubble position and size within the measured region at the photographing moment could be determined by analysis of the photo, then the phase distribution could be determined. Error analysis showed that the measurement error is usually less than 10% for low void fraction flow. So this is a lowcost and accurate measurement method.
What problem does this paper attempt to address?