Advantage of Real-Time Holography Used in Diagnostic Research of Plasma Radiating Violently

DONG Xiaogang,YAN Sixian,CHU Renxin,YANG Yi
DOI: https://doi.org/10.3321/j.issn:1000-0054.2001.03.024
2001-01-01
Abstract:In light of the practical difficulties of tests with strong and band-wide radiating and progressing swiftly, based on author's theoretical analysis and experimental investigation, this paper discussed the light intensity matching and interferential filtering with holo-grating in laser real-time holography and pointed out, in addition to the band-passing, polarity checking and space-coordinating filtrations, that the suitable allocation of ratio between object beam and reference beam by means of the introduction of the gradual light absorbing plate and in particular the proper selection of the interference terms can get the jamming light off, reconstruct the phase-field distributing on real-time and guarantee quality of interferogram and, make the application of real-time holometry become feasible and flexible and have rather advantage to the diagnostic research of the progressing states of high-temperature dense plasmas such as Z-pinch and DPF, whose strong radiation with high-exciting and high-ionizing presents numerous difficulties as performing the ordinary optical and holographic tests.
What problem does this paper attempt to address?