Analysis and Testing of Automotive MR Fluid Shock Absorber Based on Poiseuille Flow Mode

廖昌荣,余淼,李立新,杨建春,陈伟民,黄尚廉
DOI: https://doi.org/10.3969/j.issn.1674-0068.2001.05.015
IF: 1.09
2001-01-01
Chinese Journal of Chemical Physics
Abstract:Analysis methodology and design theory of magnetorheological fluid (MR fluid) shock absorber based on of Poiseuille flow mode have been parented using Newton fluid model nonlinear Bingham plastic model. In the light of the technician requirements for Changan mini - automobile, a MR fluid shock absorber has been designed and fabricated using commercial MR fluid. We have validated experimentally the nonlinear MR fluid shock absorber model. The experimental results reveal that the analysis methodology and design theory is reasonable and the MR fluid shock absorber for a specific application can be designed according to the design methodology developed.
What problem does this paper attempt to address?