Indirect Differential Pulse Voltammetric Determination of Aluminum Biological Samples in the Presence of 3, 4-Dihydroxyphenylalanine

FP Zhang,SP Bi,F Liu,NS Bian
DOI: https://doi.org/10.1080/00032710008543047
2000-01-01
Analytical Letters
Abstract:ABSTRACT Indirect differential pulse voltammetric (DPV) determination of aluminum in the presence of 3, 4-dihydroxyphenylalanine (L-dopa) with glass carbon electrode as working electrode has been described. The method relies on the decrease of DPV anodic peak current of L-dopa with the addition of AlIII The decreasing value of the peak current is linear with the increase of AlIII concentration. Under the optimum experimental conditions (pH 4.8, 6×10−4 M L-dopa, 0.06M NaAc - HAc 1buffer solution), the linear ranges are 4.0×10−7 - 5.2×10−6 M and 7.2×10−6 - 4.5×10−5 M. The relative standard deviation for 8×10−6 M aluminum is 1.0% (n = 8) and the detection limit is 3.5×10−7 M. A number of foreign species for interference have been studied. The method has been applied to determine aluminum in drinking water, synthetic renal dialysate and urine samples.