A Compound Test with High Confidence Level for Gross Error Detection

XR Wang,G Rong
DOI: https://doi.org/10.2495/data980121
2000-01-01
Abstract:Measured process data are inherently inaccurate and violate process constraints because of their underlying stochastic properties and possible gross errors caused by process disturbances, malfunctioning or miscalibrated instrumentation and even process leaks, etc. Therefore, the theory of gross error detection (GED) and data reconciliation has been developed to solve the contradictions between the measurements and their constraints. A number of gross error detection techniques are widely applied in different chemical processes. However, their performances have not always been so satisfactory: if the probability of type I error is low then that of type II error is always quite high. Here a compound test with high confidence level (HCL test) is presented in this paper, which has a low percentage of both two types of errors. Moreover, a practical example based on real process data is provided and a comparison with other tests proves that the new method is quite effective.