Three-dimensional pumping capacity in a stirred tank

Deming Mao,Lianfang Feng,Kai Wang
1997-01-01
Abstract:Pumping capacity of flow generated by impeller stirring in a baffled tank was analyzed, and some mistakes on which were pointed out. Three-dimensional total pumping capacity was defined and measured by Laser Doppler Anemometer, and the tangent pumping capacity studied little was also defined, which should be more be more accurate for agitators design. For the Disc Turbine, when the clearance was T/3, the axial total pumping capacity or radial total pumping capacity was about 1. 9; when the clearance was T/2, the axial total pumping capacity or radial pumping capacity was about 2. 3. The tangent pumping capacity was 0. 55 in two kinds of clearance. Such conceptions were easily extended to other typical impellers.
What problem does this paper attempt to address?