Simulation Analysis of Transmission-Line Impedance Transformers for Petawatt-Class Pulsed Power Accelerators
Hu Yixiang,Sun Fengju,Huang Tao,Qiu Aici,Cong Peitian,Wang Liangping,Zeng Jiangtao,Li Yan,Zhang Xinjun,Lei Tianshi
DOI: https://doi.org/10.1088/1009-0630/13/4/20
2011-01-01
Plasma Science and Technology
Abstract:Based on the transmission line code TLCODE,a 1D circuit model for a transmissionlineimpedance transformer was developed and the simulation results were compared with thosein the literature.The model was used to quantify the efficiencies of voltage-transport,energytransportand power-transport for a transmission-line impedance transformer as functions of Ψ(theratio of the output impedance to the input impedance of the transformer)and Γ(the ratio of thepulse width to the one-way transit time of the transformer)under a large scale of m(the coefficientof the generalized exponential impedance profile).Simulation results suggest that with the increasein Γ,from O to ∞,the power transport efficiency first increases and then decreases.The maximumpower transport efficiency can reach 90% or even higher for an exponential impedance profile(m=1).With a consideration of dissipative loss in the dielectric and electrodes of the transformer,tworepresentative designs of the water-insulated transformer are investigated for the next generationof petawatt-class z-pinch drivers.It is found that the dissipative losses in the electrodes arenegligibly small,below 0.1%,but the dissipative loss in the water dielectric is about 1% to 4%.