Temperature Rise During Deep Surge in Centrifugal Compression System

Ji Dai,Chuangang Gu,Yongmiao Miao
DOI: https://doi.org/10.1115/95-gt-438
1995-01-01
Abstract:A theoretical model for temperature calculation is presented to understand the tendency of temperature rise during deep surge in a low-speed centrifugal compression system. The one-dimensional aerodynamic equations of unsteady incompressible flow are employed in all components of the system. The equations are suitable to the impeller as well as the stationary parts. The one-dimensional time varied coordinate and control volume approaches for numerical scheme are used in the model. If flow rates in every deep surge cycle are provided from transients calculation or experimental data, the temperature in any position of the system can be evaluated at any step of time. A small low-pressure centrifugal compressor facility for surge experiments is set up. The dynamic measurements for flow and temperature during deep surge are implemented, and the data from measurements can be applied to verify the reliability of present model. Some phenomena can also be discovered from experimental observations. Based on the present experimental and numerical investigations, the characteristics of temperature rise during deep surge are analyzed for different volumes of system and different boundary conditions. Some results are concluded, which are valuable in engineering.
What problem does this paper attempt to address?