A 2.45 Ghz Electron Cyclotron Resonance Proton Ion Source and A Dual-Lens Low Energy Beam Transport
W. H. Zhang,H. Y. Ma,Y. Yang,Q. Wu,X. Z. Zhang,H. Wang,B. H. Ma,Y. C. Feng,X. Fang,J. W. Guo,Y. Cao,X. X. Li,Y. H. Zhu,J. Y. Li,S. Sha,W. Lu,S. H. Lin,X. H. Guo,H. Y. Zhao,L. T. Sun,D. Z. Xie,S. X. Peng,Z. W. Liu,H. W. Zhao
DOI: https://doi.org/10.1063/1.3669802
IF: 1.6
2012-01-01
Review of Scientific Instruments
Abstract:The structure and preliminary commissioning results of a new 2.45 GHz ECR proton ion source and a dual-lens low energy beam transport (LEBT) system are presented in this paper. The main magnetic field of the ion source is provided by a set of permanent magnets with two small electro-solenoid magnets at the injection and the extraction to fine tune the magnetic field for better microwave coupling. A 50 keV pulsed proton beam extracted by a three-electrode mechanism passes through the LEBT system of length of 1183 mm. This LEBT consists of a diagnosis chamber, two Glaser lenses, two steering magnets, and a final beam defining cone. A set of inner permanent magnetic rings is embedded in each of the two Glaser lenses to produce a flatter axial-field to reduce the lens aberrations.