Determination of Organotin Compounds in Wine by Microwave-Assisted Extraction and High Performance Liquid Chromatography–Inductively Coupled Plasma Mass Spectrometry

Ying-Xia Liu,Yi-Qun Wan,Lan Guo
DOI: https://doi.org/10.1080/00032719.2013.834445
2013-01-01
Analytical Letters
Abstract:A new analytical procedure for the determination of five organotin compounds in several matrix wine samples is reported. The organotin compounds were extracted by microwave-assisted extraction with n-hexane. Extraction conditions, such as volume of n-hexane required, extraction temperature, and extraction time, were investigated and optimized by an orthogonal array experimental design. The determination of organotin compounds in the final extracts was carried out by liquid chromatography-inductively coupled plasma mass spectrometry. The procedure showed limits of detection between 0.029-0.049 mu g center dot L-1. The linearity was in the range of 0.5 to 100 mu g center dot L-1. The precision expressed as relative standard deviation (RSD) was below 9.43%. The developed method was successfully employed to analyze different matrix wine samples, and some analytes were detected at the level of 0.053 to 1.14 mu g center dot L-1.
What problem does this paper attempt to address?