Liquid Density of HFE-7200 and HFE-7500 from T=(283 to 363)K at Pressures Up to 100Mpa

Dan Fang,Ying Li,Xianyang Meng,Jiangtao Wu
DOI: https://doi.org/10.1016/j.jct.2013.09.035
IF: 3.269
2014-01-01
The Journal of Chemical Thermodynamics
Abstract:The liquid densities of HFE-7200 (1-ethoxy-1,1,2,2,3,3,4,4,4-nonafluorobutane, CAS Registry Number: 163702-05-4) and HFE-7500 (3-ethoxyperfluoro(2-methylhexane), CAS Registry Number: 297730-93-9) have been measured over the temperature range from (283 to 363) K and pressures up to 100 MPa by using a high pressure vibrating-tube densimeter. R134a has been used as a reference fluid to validate the densimeter. The uncertainty of each obtained datum was estimated, and the maximum expanded uncertainty with a level of confidence of 0.95 (k = 2) of density measurement for HFE-7200 and HFE-7500 were 0.04% and 0.03%, respectively. The measured liquid densities were correlated with the modified Tait equation and the maximum deviation is less than 0.03%. The isothermal compressibility and isobaric thermal expansivity were also calculated. (C) 2013 Elsevier Ltd. All rights reserved.
What problem does this paper attempt to address?