Biological phosphorus and nitrogen removal in a sequencing batch reactor (SBR) operated in static/aerobic/anoxic regime

Dechao Xu,Hongbo Chen,Xiaoming Li,Qi Yang,Tianjing Zeng,Guan Luo,Bo Peng,Zhilong Wang,Jici Xie
2014-01-01
Abstract:A sequencing batch reactor (SBR) (R1) with static/aerobic/anoxic regime was used for biological nutrient removal (BNR). To investigate the feasibility of static phase as a substitute for conventional anaerobic phase, the performance of R1 was compared to anaerobic/aerobic/anoxic SBR (R2). The concentrations of influent acetate, ammonia nitrogen (NH4 +-N) and phosphate (PO4 3--P) in both reactors were 350 mg�� L-1, 40 mg �� L-1 and 12 mg �� L-1, respectively, and the hydraulic retention time (HRT) was 12 h. The experimental results demonstrated that the phosphorus (P) removal efficiency in R1 (92.4%) was comparative to R2 (92.1%). However, total nitrogen (TN) removal efficiency of R1 (83.5%) was higher than that of R2 (77.0%). Static phase in R1 still worked as anaerobic phase without stirring, which contributed to rapid P uptake in aerobic phase. The effluent P of 0.91 mg �� L-1 was achieved through denitrifying P removal in anoxic phase. Simultaneous nitrification and denitrification (SND) in aerobic phase contributed 18.0% of TN elimination in R1, much higher than that of R2 (9.8%). In the post-anoxic phase, microorganisms utilized glycogen as carbon source to drive denitrification, exhibiting denitrification rates (DNRs) of 0.98, 0.84 mg �� g-1 �� h-1 and 6.62, 9.21 mg �� L-1 of effluent TN in R1 and R2, respectively. Better nitrogen removal efficiency was obtained with anaerobic phase replaced by static phase, and the configuration was further simplified.
What problem does this paper attempt to address?