A Method of Measurement of 239pu, 240pu, 241pu in High U Content Marine Sediments by Sector Field ICP–MS and Its Application to Fukushima Sediment Samples

Wenting Bu,Jian Zheng,Qiuju Guo,Tatsuo Aono,Hirofumi Tazoe,Keiko Tagami,Shigeo Uchida,Masatoshi Yamada
DOI: https://doi.org/10.1021/es403500e
IF: 11.4
2013-01-01
Environmental Science & Technology
Abstract:An accurate and precise analytical method is highly needed for the determination of Pu isotopes in marine sediments for the long-term marine environment monitoring that is being done since the Fukushima Dai-ichi Nuclear Power Plant accident. The elimination of uranium from the sediment samples needs to be carefully checked. We established an analytical method based on anion-exchange chromatography and SF-ICP-MS in this work. A uranium decontamination factor of 2 x 10(6) was achieved, and the U concentrations in the final sample solutions were typically below 4 pg mL(-1) thus no extra correction of U-238 interferences from the Pu spectra was needed. The method was suitable for the analysis of Pu-241 in marine sediments using large sample amounts (> 10 g). We validated the method by measuring marine sediment reference materials and our results agreed well with the certified and the literature values. Surface sediments and one sediment core sample collected after the nuclear accident were analyzed. The characterization of Pu-241/Pu-239 atom ratios in the surface sediments and the vertical distribution of Pu isotopes showed that there was no detectable Pu contamination from the nuclear accident in the marine sediments collected 30 km off the plant site.
What problem does this paper attempt to address?