Evaluation of containment venting strategy via VFS path for advanced passive PWR NPP

K. Yuan,D. Q. Guo,L. L. Tong,Xuewu Cao
DOI: https://doi.org/10.1016/j.pnucene.2014.01.002
IF: 2.461
2014-01-01
Progress in Nuclear Energy
Abstract:Containment would be suffered by over-pressurization if passive containment cooling system (PCS) is failed to remove the heat for the advanced passive pressurized water reactor (PWR). Containment depressurization should be evaluated. Severe accident sequence induced by large break loss of coolant accident (LB-LOCA) at belt of vessel is selected to evaluate the effectiveness of containment venting strategy for advanced passive PWR with the integral safety analyses code, focusing on containment behaviors. Different sizes of the venting path and different open/close pressures of venting are investigated to evaluate CsI mass fraction released to the environment through Containment Air Filtration System (VFS). The results show that depressurization strategy by using the path of VFS can mitigate the high pressure risks and prevent the containment failure when PCS can't be initiated. High pressure at start of venting would reduce the operation times for operator to open the VFS path, reduce the radioactive released to the environment and delay the release time. The Containment Filtered Venting System (CFVS) used in generation II PWR can maintain the containment pressure below the design pressure and reduce the radioactive release for the advanced passive PWR. However much more steam is generated by In-Vessel Retention (IVR) measure, the venting capability is not enough to make the pressure at low value and the venting path should be enlarged.