Assessment of the Fetal Interventricular Septum Using Real‐time Three‐dimensional Echocardiography with Live 3D Imaging
Yi Xiong,Y. Wah,M. Chen,Tung Fung,Tak Yeung Leung,Tze Kin Lau
DOI: https://doi.org/10.1002/uog.7644
2010-01-01
Abstract:Real- time three-dimensional (3D) echocardiography is a relatively new method of examination based on two-dimensional (2D) matrix-array probe technologies. There are two major application methods of real-time 3D echocardiography—Live 3D imaging and Live xPlane imaging. We have previously reported the protocol of how to examine the fetal interventricular septum (IVS) using the Live xPlane imaging technique1. Live 3D imaging is a different technique, in which all channels of a 2D matrix probe are used to transmit and receive ultrasound pulses, generating real-time 3D images with image quality that is comparable to that of traditional 2D transducers2. These 3D volumes can be manipulated either in real time or after the images are frozen, and can be reviewed using the 'cine' function in the same way as 2D ultrasound. This is particularly useful in the visualization and examination of the pulsating fetal heart in real time3-5. The use of Live 3D imaging has been extensively reported in adult and pediatric cardiology, and has been shown to be particularly useful in the assessment of valvular diseases and congenital heart diseases6. However, its application in fetal echocardiography is still limited. We have developed, and report here, the methodology of acquisition and examination of the en face view of the fetal IVS using Live 3D imaging in 154 fetuses. All examinations were performed using an iU-22 ultrasound scanner (Philips Medical System, Bothell, WA, USA) with a 7–2-MHz matrix-array transducer (X7-2). No special preparation of patients was required. Initially, an apical four-chamber view of the fetal heart was acquired (Figure 1a). Next, the live 3D function was activated. The acquisition angle was adjusted to 72° to cover the whole fetal heart, and the volume was then cropped by the green box (along the z-axis) to display the 3D image of the four-chamber view (Figure 1b). When the fetus remained quiescent for 1 to 2 seconds, the 'freeze' button was pressed. This produced a cine-loop of real-time 3D volumes. By using the 'cine' function, the best volume was chosen. The volume was then cropped along the x-axis by moving the red box to the right side of the IVS on the four-chamber view (Figure 1c). The resultant volume was then turned 90° along the y-axis to ensure that the right side of the IVS faced the operator (Figure 1d). The last step was to perform additional cropping of the volume dataset along the original z-axis, which was accomplished by scrolling back the green box (Figure 1e). Step-by-step demonstration of the use of Live 3D imaging to visualize the en face view of the fetal interventricular septum (IVS) in a normal case. See text for description of parts a–e. AO, aorta; APEX, cardiac apex; PV, pulmonary valve; RA, right atrium. In the first 20 cases, the subcostal four-chamber view approach was also studied and was found to produce an inferior live 3D image quality as a result of acoustic shadowing from the overlying rib cage. A total of 154 fetuses were scanned, with a mean (± SD) maternal body mass index of 21.2 ± 2.8 (range 16.3–32.1), similar to that of our obstetric population. Overall, 58 (37.7%) cases were at or before 24 weeks, and 96 (62.3%) were between 25 and 30 weeks. An en face view of the IVS was successfully visualized by Live 3D imaging in all except one case. The cardiac apex was at about 12 o'clock and 6 o'clock positions in 85 (55.6%) and 68 (44.4%) cases, respectively. Once an apical four-chamber view was obtained, the use of Live 3D imaging enabled a quick volume-rendered display of the en face view of the IVS. Figure 2a shows the en face view of a normal IVS. En face view of the fetal interventricular septum displayed by Live 3D imaging in a normal case (a) and in a case with a ventricular septal defect (b). The outline of the septum is indicated by the arrows. AO, aorta; APEX, cardiac apex; PV, pulmonary valve; RA, right atrium; VSD, ventricular septal defect. There were seven cases with congenital cardiac anomalies, including one case of an isolated ventricular septal defect (VSD) (Figure 2b), one case of an atrioventricular septal defect, three cases of truncus arteriosus with VSD, one case of tetralogy of Fallot and one case of transposition of the great arteries without VSD. Using Live 3D imaging, the VSDs in the first six cases and the intact septum of the last case were successfully displayed. The abnormalities of all seven cases were confirmed either by autopsy or by postnatal echocardiography and surgery. Live 3D imaging allowed the rapid volume-rendered display of the en face view of IVS without the need of transducer movement. There are two obvious advantages of this approach. First, acquisition is relatively easy and quick. Second, fetal movement artifact is not a problem because it takes little time to take an image shot. Once the 'freeze' button is pressed, the volume data cine-loop will be stored and available for review and analysis. The en face view of IVS could be obtained by cropping the 3D volumes along the x-axis and then rotating the 3D volumes along the IVS according to standardized steps. Live 3D imaging potentially may be a useful tool for the assessment and diagnosis of fetal VSDs and other congenital heart defects, and further studies are necessary to explore its role in fetal echocardiography. Y. Xiong* , Y. M. I. Wah*, M. Chen*, T. Y. Fung*, T. Y. Leung*, T. K. Lau*, * Fetal Medicine Unit, Department of Obstetrics and Gynaecology, Prince of Wales Hospital, The Chinese University of Hong Kong, Hong Kong, Department of Ultrasound, Shenzhen People's Hospital, Jinan University, Shenzhen, China