Ground Simulation of Leak Detection and Localization of Space Station with Direction Gauge

卢耀文,陈旭,李得天,闫荣鑫,冯焱,成永军,赵澜,齐京,查良镇
DOI: https://doi.org/10.3969/j.issn.1672-7126.2013.12.02
2013-01-01
Abstract:A novel technique was developed to simulate on the ground the leak detection and leakspot localization of the space-station. The possible small leak was modeled , approximated, and experimentally simulated. In the ground simulation, a small amou nt of gas was injected into the dedicated vacuum chamber, and the leak spot can b e located by measuring two variables: the direction from gauge to the leaking spo ts was estimated by changing the angle letween the gauge inlet normal and the or ifice axis with the magnetic force driving unit, and the distancebetween gauge a nd the leak spot was evaluated by measuring the gauge position on te fixed brack et with a dividing ruler. Assuming the distribution of the leaked molecules obeys the cosine-law, the simulated results show that the direction gauge is capable of approximately locating the leak spot and evaluating the leak rate by scanning the suspected area. The technical problems to be solved in leak detection of spa ce-station with direction gauge were also tentatively discussed.
What problem does this paper attempt to address?