Process design and water purification efficiency of one water treatment plant in America

姚宏,张士超,周小轮,王春荣
2013-01-01
Abstract:This paper introduced the ozone-biological activated carbon process, main structures, design parameters and operating effect of a water supply plant in United States. The results show that: TSS, BOD5, COD, UV254 and turbidity of the raw wastewater were 18.25 mg/L, 5 mg/L, 7.34 mg/L, 0.08 and 17.38 NTU, respectively, the quota of the treated water were 1.33 mg/L, 2 mg/L, 0 mg/L, 0.01 and 0.86 NTU. Their removal rates of the total process were 88%, 60%, 100%, 88%, 81%, respectively. The application of this process in water purification had good effect, and these conventional indexes met the requirement of our country's Life Sanitary Standard For Drinking Water (GB5749-2006), so the advanced treatment technologies and design ideas are worth our learning and reference.