Flexural and compressive mechanical behaviors of the porous titanium materials with entangled wire structure at different sintering conditions for load-bearing biomedical applications.

Guo He,Ping Liu,Qingbiao Tan,Guofeng Jiang
DOI: https://doi.org/10.1016/j.jmbbm.2013.08.016
IF: 4.042
2013-01-01
Journal of the Mechanical Behavior of Biomedical Materials
Abstract:The entangled titanium materials with various porosities have been investigated in terms of the flexural and compressive mechanical properties and the deformation and failure modes. The effect of the sintering parameters on the mechanical properties and the porosity reduction has been comprehensively studied. The results indicate that both the flexural and compressive mechanical properties increase significantly as the porosity decreases. In the porosity range investigated the flexural elastic modulus is in the range of 0.05–6.33GPa, the flexural strength is in the range of 9.8–324.9MPa, the compressive elastic modulus is in the range of 0.03–2.25GPa, and the compressive plateau stress is in the range of 2.3–147.8MPa. The mechanical properties of the entangled titanium materials can be significantly improved by sintering, which increase remarkably as the sintering temperature and/or the sintering time increases. But on other hand, the sintering process can induce the porosity reduction due to the oxidation on the titanium wire surface.
What problem does this paper attempt to address?