Wind-resistant behavior of a long span cable-stayed bridge during construction

Ting-ting MA,Yao-jun GE,Lin ZHAO
DOI: https://doi.org/10.13465/j.cnki.jvs.2013.12.026
2013-01-01
Abstract:A long span cable-stayed bridge is a kind of flexible structure sensitive to wind effects, especially, during construction. Its wind-resistant behavior during two types of construction process including single-cantilever and double-cantilever was studied via numerical methods. The results showed that the lateral bending and torsional fundamental frequencies decrease with increase in the single-cantilever length, while the vertical bending one has a rising tendency until the cantilever length reaches 250 m; with increase in the double-cantilever length, all the three fundamental frequencies decrease, the lateral bending one decreases most quickly; moreover, the vertical buffeting response increases linearly within the single-cantilever length of 300 m; the same law appears for the lateral bending one until the single-cantilever length reaches 200 m, when it is larger than 200 m, the lateral buffeting response increases obviously; for double-cantilever construction, within the cantilever length of 200 m the buffeting response is rising linearly and slowly; the buffeting responses of single-cantilever construction are generally contributed by the first vibration mode of the girder and significantly influenced by the second mode; for those of double- cantilever construction, however, the symmetric vibration modes contribute more to the buffeting responses.
What problem does this paper attempt to address?