Adaptability of PIV Based on Different Working Principle to Turbulence Measurements

杨胜发,王兴奎,胡江,兰艳萍
2013-01-01
Abstract:Adaptability of monopulse PIV and double-pulse PIV to turbulent flow measurements are analyzed in this paper,using experimental data of flows in a chute and considering the difference in PIV working principles,statistical methods of data processing,and their requirements for data sample size.Both double-pulse PIV and high-frequency monopulse PIV(higher than 100Hz) are fit for turbulence measurement.If its frequency is lower than 50Hz,monopulse PIV is fit for time-average velocity only.Among the three traditional methods for data processing,time-average method and statistical average method can be used for monopulse PIV data,while only the latter method can be used for double-pulse PIV data.In measurement of time-average velocity,both PIV systems perform well if sample size is over 500,while in measurement of turbulence characteristics,the size must be increased to at least 3,000 and 5,000 for monopulse PIV and double-pulse PIV,respectively.
What problem does this paper attempt to address?