Design and analysis of blast test of underground arch structure

Peng WANG,Jiannan ZHOU,Fengnian JIN,Zhigao XIA,Hualin FAN
DOI: https://doi.org/10.3969/j.issn.1009-3443.2012.12.180
2013-01-01
Abstract:To research the response of arch structure under dynamic loading,an explosion test was designed according to the explosion principle,theory of sensor technology and the requirements of explosion on un-derground arch structure.The arch structure made by reinforced concrete was buried after installing sen-sors.In order to obtain valid measurement data,several types of sensors were used in the tests,including strain sensor,acceleration sensor,pressure sensor,displacement sensor,etc.In this paper,the basic re-quirements of explosion experiment on underground arch structure,as well as its basic principle,were in-troduced,and the dynamic test system mainly composed of sensors,initiation of explosion and synchro-nized trigger and data acquisition and storage,was constructed.Judged from the phenomena and results, this test can meet the requirements of blast test,and provide the reference for other similar test and the basis of the design of underground arch structure.