Abstract:A real-time correction method for range walk error in photon counting 3D imaging Lidar is proposed in this paper. We establish the photon detection model and pulse output delay model for GmAPD, which indicates that range walk error in photon counting 3D imaging Lidar is mainly effected by the number of photons during laser echo pulse. A measurable variable - laser pulse response rate is defined as a substitute of the number of photons during laser echo pulse, and the expression of the range walk error with respect to the laser pulse response rate is obtained using priori calibration. By recording photon arrival time distribution, the measurement error of unknown targets is predicted using established range walk error function and the range walk error compensated image is got. Thus real-time correction of the measurement error in photon counting 3D imaging Lidar is implemented. The experimental results show that the range walks error caused by the difference in reflected energy of the target can be effectively avoided without increasing the complexity of photon counting 3D imaging Lidar system.
What problem does this paper attempt to address?