Portable and Quantitative Monitoring of Heavy Metal Ions Using DNAzyme-capped Mesoporous Silica Nanoparticles with a Glucometer Readout.

Libing Fu,Junyang Zhuang,Wenqiang Lai,Xiaohua Que,Minghua Lu,Dianping Tang
DOI: https://doi.org/10.1039/c3tb21155j
IF: 7.571
2013-01-01
Journal of Materials Chemistry B
Abstract:A portable and quantitative monitoring protocol for sensitive detection of lead ions is designed, based on target-responsive cargo release from Pb2+-specific DNAzyme-capped mesoporous silica nanoparticles (MSNs), by coupling with a widely accessible personal glucose meter (PGM). Initially, glucose molecules are loaded into the pores of the MSNs, the pores are then capped with Pb2+-specific DNAzymes. Upon target introduction, the molecular gates open, resulting in release of the cargo from the pores. The released glucose can be quantitatively monitored using a portable PGM. Under optimal conditions, the as-prepared sensing platform presents good analytical properties for the determination of the target Pb2+ ions, and allows detection of Pb2+ at concentrations as low as 1.0 pM. Importantly, the portable sensing platform has the advantages of simple, on-site, user-friendly and low-cost assessment and has tremendous potential for quantitative detection of non-glucose targets by the public.
What problem does this paper attempt to address?