High-throughput radio-TLC analysis
Jia Wang,Alejandra Rios,Ksenia Lisova,Roger Slavik,Arion F Chatziioannou,R Michael van Dam,Arion F. Chatziioannou,R. Michael van Dam
DOI: https://doi.org/10.1016/j.nucmedbio.2019.12.003
IF: 2.947
2020-03-01
Nuclear Medicine and Biology
Abstract:<h3 class="u-h4 u-margin-m-top u-margin-xs-bottom">Introduction</h3><p>Radio thin layer chromatography (radio-TLC) is commonly used to analyze purity of radiopharmaceuticals or to determine the reaction conversion when optimizing radiosynthesis processes. In applications where there are few radioactive species, radio-TLC is preferred over radio-high-performance liquid chromatography due to its simplicity and relatively quick analysis time. However, with current radio-TLC methods, it remains cumbersome to analyze a large number of samples during reaction optimization. In a couple of studies, Cerenkov luminescence imaging (CLI) has been used for reading radio-TLC plates spotted with a variety of isotopes. We show that this approach can be extended to develop a high-throughput approach for radio-TLC analysis of many samples.</p><h3 class="u-h4 u-margin-m-top u-margin-xs-bottom">Methods</h3><p>The high-throughput radio-TLC analysis was carried out by performing parallel development of multiple radioactive samples spotted on a single TLC plate, followed by simultaneous readout of the separated samples using Cerenkov imaging. Using custom-written MATLAB software, images were processed and regions of interest (ROIs) were drawn to enclose the radioactive regions/spots. For each sample, the proportion of integrated signal in each ROI was computed. Various crude samples of [<sup>18</sup>F]fallypride, [<sup>18</sup>F]FET and [<sup>177</sup>Lu]Lu-PSMA-617 were prepared for demonstration of this new method.</p><h3 class="u-h4 u-margin-m-top u-margin-xs-bottom">Results</h3><p>Benefiting from a parallel developing process and high resolution of CLI-based readout, total analysis time for eight [<sup>18</sup>F]fallypride samples was 7.5 min (2.5 min for parallel developing, 5 min for parallel readout), which was significantly shorter than the 48 min needed using conventional approaches (24 min for sequential developing, 24 min for sequential readout on a radio-TLC scanner). The greater separation resolution of CLI enabled the discovery of a low-abundance side product from a crude [<sup>18</sup>F]FET sample that was not discernable using the radio-TLC scanner. Using the CLI-based readout method, we also observed that high labeling efficiency (99%) of [<sup>177</sup>Lu]Lu-PSMA-617 can be achieved in just 10 min, rather than the typical 30 min timeframe used.</p><h3 class="u-h4 u-margin-m-top u-margin-xs-bottom">Conclusions</h3><p>Cerenkov imaging in combination with parallel developing of multiple samples on a single TLC plate proved to be a practical method for rapid, high-throughput radio-TLC analysis.</p>
radiology, nuclear medicine & medical imaging