Performance comparison between U-U and Z-Z type parallel arrangement of mini-hydrocyclone group

HUANG Cong,WANG Hualin,CHEN Cong,LIU Jinming,WU Ruihao
DOI: https://doi.org/10.3969/j.issn.0438-1157.2013.02.029
2013-01-01
Abstract:It is common to use multiple mini-hydrocyclones in parallel arrangement for large-scale industrial applications. For two typical parallel arrangements in mini-hydrocyclone group, U-U type and Z-Z type, the characteristics of pressure drop and flow distribution were investigated and compared by using theoretical model and experiments. It is found theoretically that the value of Q3+R2 has great influence on the performance of both parallel arrangements, where Q and R represent the momentum and the friction effects. The performance of U-U arrangement is better if Q3+R2<0, while that of Z-Z arrangement is better if Q3+R2>0. The experimental results show that the Z-Z arrangement presents better pressure drop distribution than the U-U type for 0.05≤P<0.10 MPa, but the flow distribution of both parallel arrangements is non-uniform under the condition. At P=0.10 MPa, uniform pressure drop and flow distribution are found for both arrangements. For 0.10<P≤0.15 MPa, the flow distribution of U-U arrangement is more uniform than Z-Z type. The pressure drop distribution of both arrangements has the same trend and is good. © All Rights Reserved.