Adsorption of hexavalent chromium from aqueous solutions by graphene modified with cetyltrimethylammonium bromide.

Yan Wu,Hanjin Luo,Hou Wang,Can Wang,Jian Zhang,Zilong Zhang
DOI: https://doi.org/10.1016/j.jcis.2012.11.049
IF: 9.9
2013-01-01
Journal of Colloid and Interface Science
Abstract:In this study, cetyltrimethylammonium bromide was chosen to modify graphene, which was prepared using a modified Hummers’ method. The characteristics of graphene and modified graphene were characterized by X-ray diffraction, Fourier transform infrared spectrum, X-ray photoelectron spectroscopy, transmission electron microscopy, and scanning electron microscopy. The effect factors including pH, contact time, temperature, and dosage on the adsorption properties of Cr(VI) onto graphene and modified graphene were investigated. Batch experiments were conducted to evaluate the adsorbance of Cr(VI) from aqueous solution using graphene and modified graphene as the adsorbent under different conditions. The results revealed that the optimal pH for the adsorption was about 2, and the best suitable temperature was at 293K. The adsorption processes were rapid within the first 5min and reached equilibrium in about 40min. The adsorption kinetics fitted well with pseudo-second-order model. The adsorption capacity of Cr(VI) on modified graphene inferred from the Langmuir model was 21.57mg/g at 293K. The thermodynamic parameters indicated that the adsorption of Cr(VI) onto modified graphene was an exothermic and spontaneous process.
What problem does this paper attempt to address?