Welding Arc Temperature Field Measurements Based on Boltzmann Spectrometry

Si Hong,Hua Xue-ming,Zhang Wang,Li Fang,Xiao
DOI: https://doi.org/10.3964/j.issn.1000-0593(2012)09-2311-03
2012-01-01
Abstract:Arc plasma, as non-uniform plasma, has complicated energy and mass transport processes in its internal, so plasma temperature measurement is of great significance. Compared with absolute spectral line intensity method and standard temperature method, Boltzmann plot measuring is more accurate and convenient. Based on the Boltzmann theory, the present paper calculates the temperature distribution of the plasma and analyzes the principle of lines selection by real time scanning the space of the TIG are measurements.
What problem does this paper attempt to address?