Sound Environment of Waiting Areas in Large General Hospitals in China

Xin Qin,Jian Kang,Hong Jin
DOI: https://doi.org/10.3813/aaa.918557
2012-01-01
Acta Acustica united with Acustica
Abstract:Based on field measurements and questionnaire surveys, sound environment in 150 waiting areas in 15 large modern general hospitals in China has been analysed. It has been shown that most of the waiting areas are U-shaped, where the dominant frequency range is 250 Hz-4 kHz and the maximum SPL occurs at around 1 kHz. The average LAeq in the morning is greater than that in the afternoon, with a difference of 1-7 dBA. Patients and staff believe that speech sound is the dominant sound in the waiting areas. There are statistically significant associations among the physical environmental factors, and the sound environment and light environment are most closely correlated, evaluated by both patients and staff. The sound environment satisfaction is evaluated at 'neutral' level, lower than that of other physical environmental factors. The effects of social factors of patients and staff on the evaluation of sound environment are generally insignificant.
What problem does this paper attempt to address?