Quantitative Analysis of Uncoated Eszopiclone Tablets by Near-Infrared Spectroscopy
Yanxin Liu,Wei Luo,Wan Wang,Feng Peng,Jing Wang,Hui Li
DOI: https://doi.org/10.1080/00032719.2014.888726
2014-01-01
Analytical Letters
Abstract:This study employed near-infrared (NIR) spectroscopy to analyze content uniformity, moisture content, compression force, tablet hardness, average particle size, and particle-size distribution. The content uniformity, moisture content, compression force, tablet hardness, and average particle size models yielded high correlation coefficients (R-2) of 0.99582, 0.99725, 0.99620, 0.96294, and 0.98421, respectively, whereas the particle size distribution models showed good predictive ability. Conventional criteria such as R-2, root-mean-square error of calibration, and the root-mean-square error of prediction were used to evaluate the accuracy and precision of the model. To ensure the accuracy and predictability of the content model for low-dose tablets, additional validation and reliability evaluations were performed using 70%, 80%, 100%, 120%, and 130% drug concentrations as well as 90% and 110% active content formulations. Near-infrared spectroscopy with multivariate modeling is a rapid, nondestructive technique for the characterization of the manufacturing process.