Development of an HPLC-UV Method for the Determination of Ethaselen in Its Injection Formulation

Su Chen,Ping Song,Ying Wang,Qi-Zhi Hu,Xuan Zhang,Qiang Zhang
DOI: https://doi.org/10.5246/jcps.2012.04.043
2012-01-01
Journal of Chinese Pharmaceutical Sciences
Abstract:A novel ethaselen injection formulation has been developed in our laboratory.The objective of the present study was to establish and validate a high performance liquid chromatography (HPLC) method for the determination of ethaselen in its injection formulation.Analysis was performed on an ODS column with isocratic elution at 40 ℃.Mobile phase was consisted of 0.01% phosphoric acid and methanol (60∶40,v/v).The detection wavelength was set at 320 nm and the flow rate was 1.0 mL/min.The results showed that the calibration curves of ethaselen were linear in the range of 10-50 μg/mL (r2 =0.9999).The limit of detection for ethaselen was 100 ng/mL.The average recovery of ethaselen was 100.14%.The labeled content of ethaselen in its injection formulation was in the range of 102%-103% of the measured content.In conclusion,this method was stable and reproducible,thus providing a useful tool for the routine analysis of this novel ethaselen injection formulation.
What problem does this paper attempt to address?