Development of a latex microsphere-based lateral flow immunoassay for the diagnosis of schistosomiasis japonica
Emmanuel John Tabilin,Catherine A. Gordon,Yi Mu,Mario Jiz,Marianette Inobaya,Eleonor Avenido-Cervantes,Darren Gray,Mary Lorraine Mationg,Donald P. McManus,Thomas G. Egwang,Moses Adriko,Yasuhito Sako,Marcello Otake Sato,Megumi Sato,Hong You,Matthew Kelly,Pengfei Cai
DOI: https://doi.org/10.1371/journal.pntd.0012742
2024-12-17
PLoS Neglected Tropical Diseases
Abstract:Zoonotic schistosomiasis, caused by Schistosoma japonicum , is prevalent in China, the Philippines and Indonesia. Rapid point-of-care (POC) diagnostics are attractive and promising tools for evaluating the efficacy of intervention strategies for schistosomiasis control. The diagnostic potential of five recombinant antigens was tested by enzyme-linked immunosorbent assay (ELISA) using sera from individuals with positive Kato-Katz (KK) results for S . japonicum (n = 28) and non-endemic controls (n = 12). A latex microsphere (LM)-based lateral flow immunoassay (LFIA) incorporating the recombinant SjSAP4 (rSjSAP4) was developed for the diagnosis of schistosomiasis japonica. The test conditions including diluent, dilution factor and reaction time, were optimised for the developed LFIA. Under the optimised conditions, serum samples from individuals living in a barangay endemic for S . japonicum (n = 549) and non-endemic controls (n = 50) were tested with the established LFIA cassettes. The results were imaged by a smartphone and analysed by the ImageJ program. The intensity ratio of the test line to the control line (T/C ratio) was calculated for each cassette. ELISA confirmed that rSjSAP4 was the optimal candidate for serological diagnosis of schistosomiasis japonica. Under optimal testing conditions, the developed LFIA strips had a sensitivity of 80.6% and a specificity of 98.0% at a cut-off T/C ratio of 0.1031. Moreover, the results of the LM-based LFIA was positively correlated with those obtained from the rSjSAP4-ELISA (r = 0.8270, 95% CI, 0.7990–0.8514; p < 0.0001). The schistosomiasis prevalence determined by the LFIA strips was about 1.8 times greater than that obtained with the 6-slide KK procedure performed on three stool samples. The developed LFIA represents a POC diagnostic tool that is suitable for onsite screening of human S . japonicum infection with minimal equipment needed. The established immunochromatographic assay complies with most of the WHO's ASSURED criteria for POC diagnostics. Schistosomiasis remains a significant global public health concern, with over 230 million people affected. Integrated multicomponent interventions targeting the various aspects of schistosomiasis epidemiology represent promising efforts that may eventually lead to the disease elimination. Rapid and accurate point-of-care diagnostics (POCs) are crucial tools for informing the effective implementation of these elimination efforts. In this study, we developed a latex microsphere (LM)-based lateral flow immunoassay (LFIA) by incorporating rSjSAP4 for the rapid diagnosis of schistosomiasis japonica. Serum samples collected from subjects living in an area endemic for S . japonicum and non-endemic controls were tested with the established LFIA strips. In the individuals who tested positive by the Kato-Katz method, the LM-based LFIA cassette showed 80.6% sensitivity and 98.0% specificity. When the entire Philippines cohort was tested, the developed LFIA showed a high consistency with the rSjSAP4-ELISA. The schistosomiasis incidence deduced from the developed LFIA and rSjSAP4-ELISA was about 1.8 times higher than that determined with the KK procedure. The findings obtained here further indicate that the rSjSAP4-incorprated LFIA meets most of the ASSURED criteria set by the WHO for POC diagnostics, representing an effective diagnostic tool for the screening of S . japonicum infection in rural endemic areas with limited resources.
tropical medicine,parasitology