The use of copper(II) isonicotinate-based micro-solid-phase extraction for the analysis of polybrominated diphenyl ethers in soils.

You-Ya Zhou,Chao-Yan Zhang,Zeng-Guang Yan,Ke-Ji Li,Lin Wang,Ya-Bo Xie,Fa-Sheng Li,Zhou Liu,Jin Yang
DOI: https://doi.org/10.1016/j.aca.2012.08.023
IF: 6.911
2012-01-01
Analytica Chimica Acta
Abstract:A micro-solid-phase extraction (μ-SPE) device was developed by filling copper(II) isonicotinate coordination polymer (Cu(4-C5H4N-COO)2(H2O)4) into a porous polypropylene envelope, and the μ-SPE, coupling with gas chromatography (GC) with a micro-cell electron capture detector (μ-ECD), was used for extraction and determination of PBDEs in soils. Variables affecting extraction procedures, including temperature, water volume, extraction time, and desorption time, were investigated in a spiked soil, and the parameters were optimized. Under the optimal experimental conditions, the method detection limits for seven PBDEs (BDE-28, 47, 99, 100, 153, 154, and 183) were in the range of 0.026–0.066ngg−1, and the reproducibility was satisfactory with the relative standard deviation in range of 1.3–10.1%. Good linear relationship between PBDEs concentrations and GC signals (defined as peak area) was obtained in the range between 0.1 and 200ngg−1. The recovery of the seven PBDEs by μ-SPE varied from 70 to 90%, which was comparable to that determined by accelerated solvent extraction method. Finally, the proposed method was used to determine PBDEs in several field-contaminated soils, and it was suggested that the μ-SPE is a promising alternative microextraction technique for the detection of PBDEs in soils.
What problem does this paper attempt to address?