Research on Seismic Damage of Metro Station with Centrifuge Shaking Table Model Test

凌道盛,郭恒,蔡武军,韩超
DOI: https://doi.org/10.3785/j.issn.1008-973x.2012.12.010
2012-01-01
Abstract:In order to reveal the mechanism of metro station damage induced by seismic load,centrifuge shaking table test was carried out to simulate the seismic damage process of subway station.Using microconcrete with low strength and steel wire,a one-story two-span metro station model(1∶50 scale) was built.This model was placed in silica sand(saturated by silicone oil) by pluviation and the relative density was 45%.A vacuum saturation equipment was designed which is suitable to varisized foundation model.The dynamic responses of underground structure and sand were monitored during the accelerated process of the centrifuge and the excited process with Ninghe waves whose maximum acceleration peak values were 0.08g and 0.20g respectively.Test results showed that during the accelerated process of the centrifuge,large axial pressure was beard by the columns of station under the weight of metro station and overlying soil.Under the excitation of 0.08g Ninghe wave,the dissipation of the excess pore water pressure near the structure was much faster than that of other places in the same depth.When the model was subjected to 0.2g Ninghe wave,the bottom parts of all the three columns,which were the weak points of metro station,were damaged and there were appreciable cracks in the junction of sidewalls and base plate.