Ultrasonic inspection of liquid foodstuffs through stainless steel vessel wall for on-line monitoring

Ruifeng Meng,Xingqian Ye,Donghong Liu
2012-01-01
Abstract:The application of a non-contact ultrasonic system to measure the acoustic impedance of different liquids with more sensitive is described. A broad-band transducer is mounted directly upon a stainless steel vessel wall outside, so the vessel wall becomes part of the measurement system. Multiple reflections within the stainless steel wall are used to determine the acoustic impedance of the liquid in vessel, where the acoustic impedance is defined as the product of the density and the speed of sound. By basing the measurement on multiple reflections, instrument sensitivity is increased by the power of the reflection coefficient. Acoustic impedances of pure liquid methanol, ethanol, water, glycerin and solution of CaCl 2 are obtained. Results showed that the accuracy of the system increased with a higher acoustic impedance of measured liquid. For water and Glycerin, the relative acoustic impedance percent errors are already less than 0.2%. Also, the response of the system indicated that the solute concentration (CaCl 2) respond highly linearly to its acoustic impedance, with correlation coefficient R 2=0.9977. The measurement method is self-calibrating because the measurement of the acoustic impedance is independent of changes in the puiser voltage. And it can be used to character the very attenuative liquid foodstuffs, due to not necessary to transparent sound wave in measured liquids.