Biotoxicity removal of pharmaceutical wastewater by iron-carbon micro-electrolysis process

Can Wang,Liang Sun,XiaoFang Liu,Fen Wang,Min Ji
2012-01-01
Abstract:To evaluate the ecological safety and feasibility of micro-electrolysis processes, a multilayer micro-electrolysis reactor treating actual pharmaceutical wastewater was established. The experimental results showed that the pharmaceutical wastewater with an overall toxicity of 4.5-7.1 mg Zn 2+ L -1 was reduced to 2.4-5.7 mg Zn 2+ L -1 after treatment. With the development of influent COD concentrations from 5500 to 9000 mgL -1, the toxicity removal efficiencies rose up firstly and then decreased. While the toxicity removal rate increased continuously and finally maintained at 0.8 mg Zn 2+ L -1 h -1. The higher pH values and non aeration conditions were favorable to toxicity removal. Longer hydraulic retention time inside the reactor helped to improve the toxicity removal efficiencies. But the toxicity removal rates went up firstly and then declined. Analysis between the COD concentrations and wastewater toxicity demonstrated good linear relationships in both the influent and effluent wastewater. However, the influent COD showed a greater effect on wastewater toxicity than the effluent, suggesting detoxicity effects by micro-electrolysis.
What problem does this paper attempt to address?