Acoustic emission detection and CFD simulation of a liquid spray process

孙婧元,楼佳明,黄正梁,王靖岱,蒋斌波,阳永荣
DOI: https://doi.org/10.3785/j.issn.1008-973X.2012.02.006
2012-01-01
Abstract:In order to acquire a fast and sensitive detecting method of liquid spray performance, the acoustic emission (AE) signals originated from impact of liquid spray on the baffle were collected by the transducer located behind the baffle, and processed by multiple scanning accumulated Fast Fourier Transform. By analyzing the acoustic energy and power spectrum, a new criterion to determine the critical state in which the atomization performance became satisfied was proposed. When acoustic energy variation tended to be stable and began to rise, and the atomization dimensionless number started to grow rapidly, meanwhile the mean square deviation of acoustic energy began to ascend and become stable as the liquid flow rate increased, the liquid spray achieved the critical state of excellent atomization. After that, the improvement of atomization performance would be unconspicuous if the liquid flow rate increased further. Simultaneously, the liquid spray process was detected through image pickup and calculated by Eulerian-Lagrangian computational fluid dynamics (CFD) simulation method. The criterion was verified by the images of spray field and the simulation results, which indicated the acoustic emission detection could measure the liquid spray performance qualitatively.
What problem does this paper attempt to address?