Space Charge Distribution Characteristic in Double-layer Oil Impregnated Papers under Temperature Gradient

吴锴,朱庆东,王浩森,吕泽鹏,王霞
2012-01-01
Abstract:Temperature gradient existing in the oil impregnated paper insulation such as converting transformer or DC bushing affects the space charge distribution. The space charge profiles and field distributions in double layers of oil impregnated paper within 20 minutes were measured by the pulse electro-acoustic method under different temperature differences(Δθ=0、20、40°C), and DC voltage of - 3. 4, - 10. 2, - 20. 4 kV (DC electric field intensity of 10, 30, 60 MV/m), respectively. The test results show that homocharge exists in both electrodes when the electric field intensity was low, and the heterocharge appears in the low temperature side due to the temperature difference. Moreover, the more remarkable the temperature difference and electric filed intensity were, the more the heterocharge at the low temperature side is, resulting in a greater field distortion. The homocharge of the upelectrode starts to accumulate in the space between two layers of oil impregnated paper. The higher the temperature and electric field intensity were, the more the space charge were while the density of the charge is saturated. The result suggests that the oil paper interface plays the role in preventing the charge from passing by, and the temperature is the main factor which affects the space charge distribution and the electricity conduction of the sample.